Examining The Auto Control System Program In Hvac Anatomist Essay

With the quick development of the Computer-Based Control System, The Building Automation System (BAS) has come to control and control the accessories in a building more clinically, financially, rationally and reliably, which will not only improve the function and the comfort level of the building occupancy, but also save energy and decrease the environmental impacts.

1. Introduction

Economic development, civil, general population and commercial building central air conditioner Popularizations bring a serious energy utilization problem. The greater the quantity of air conditioner used, the more electricity expensed, it contributes to the lack of electricity and limit the municipal use of electricity in warmer summer months. HVAC system consumes around about 50%~60% of the complete building utilization in the clever building. Especially the freezes device, the cooling tower, the circulating water pump, the air conditioner and the new air unit, consume most of the energy. To be able to control and manage the air-conditioning system effectively, and take full use of energy-saving technology, we apply the Auto Control System. DDC (Direct digital control) is one of the ACS types, as the name suggests, it involves immediate digital communication between sensors, controllers, and actuators. DDC systems can be controlled by microprocessors or personal computers, which enable more flexibility in control algorithms and also allow to be checked remotely. The DDC has recently become an Open-System and implemented by the most international distributors, which mean that it can be an intrinsic Sub-LAN of any international centralized control web. The DDC (other than only an HVAC control System), can now be integrated in any BAS system through the Local BACnet network (adopted by ASHRAE). As well as the Automatic Control System request for energy conservation and high HVAC system performance, a green HVAC system design will

achieve all aspects of comfort, energy saving, low primary and operational capital costs, and gives better performance with the DDC system, a good example of such renewable HVAC system would be an Optimal Air System, and you will be talked about in this survey.

2. Auto control System

An Automatic Control System is a preset closed-loop control system that requires no operator action. This assumes the process remains in the standard range for the control system.

An Automatic Control System has two process parameters associated with it, a controlled variable and a manipulated variable.

a) A managed variable is the procedure varying that is maintained at a given value or inside a specified range.

b) A manipulated variable is the process that is acted on by the control system to keep up the handled variable at the given value or within the specified range.

2. 1 Application

Automatic controls take the data made by monitoring tools and use these data to control everything from control equipment to space cooling and heating systems. Many production processes which used to be by hand controlled are now manipulated automatically. This innovation has several benefits

a) Immediate modification of unpre

b) Dictable changes;

c) Simultaneous adjustment of many functions;and

d) Highly steady control.

The benefits realized from the utilization of automatic handles in process equipment are evident in quality and output advancements. When used for energy management applications, computerized control buttons can reduce energy costs by strictly controlling temps and stream rates and by changing lighting, motor speeds, and substance and gas moves as required by the process.

Fig 1, Typical Automatic Control system, DCS LAN layout

2. 2 Functions of Auto Control

In any automated control system, the four basic functions that occur are

a) Measurement

b) Comparison

c) Computation

d) Correction

2. 3 Elements of Automatic Control

The three functional elements had a need to perform the functions of any automated control system are

a) A dimension component (Sensor, Transmitter, Transducer)

b) An error detection component (Digital/Analog/pneumatic Controller, PCU)

c) Your final control factor (Engine/Piston Actuator, VFD, VSD, Relay)

2. 4 Remote location control and monitoring

The Auto Control System' LAN and Sub-LANs can be accessed, controlled and checked from remote locations via the Internet trough a developed centralized data management system which is capable of collecting data from multiple sites. This is accomplished by joining with a gateway for collecting data from the lighting and air-conditioning control systems installed in each building or manufacturer, and the center server for providing data collection, database and web server functions along with security methods put on all transmitted data.

Based on the ability of real-time monitoring and analysis of real energy use such as electricity and gas from a remote location by by using a web browser, this system can achieve the maximum level of energy conservation in complexes and factories which, decrease the emissions and the environmental impacts by taking good thing about its cost performance and by limiting the mandatory energy for a specific program or function.

3. Types of Automatic Control System

3. 1 Programmable logic controllers

The computerized devices mostly used in process control are programmable reasoning controllers (PLCs). A PLC system has three main components

a) Input component: devices such as limit switches, drive control keys, pressure switches, detectors, electrodes and even other PLCs provide incoming control alerts (digital or analogue) to the suggestions module. The module converts the indication to a level that can be utilized by the central handling unit (CPU) of the controller. It then electrically isolates it and transmits it to the CPU.

b) Controller: a programmable ram in the controller that stores instructions for putting into action specific functions and changes the inputs into impulses that go out of the PLC to the result module.

c) Outcome system: this technique can take the CPU's control sign (programmed instructions), isolates it electrically and energizes (or de-energizes) the module's moving over device to carefully turn on or off of the result field devices (e. g. motor starters, pilot lights and solenoids).

An exemplory case of a straightforward PLC used for energy management is one for an air-supply system. The PLC system regulates factors such as temp, air flow to various zones, moisture, filtering, shut-off of airflow to unoccupied areas and exhaust level. Larger, more technical applications require more complex PLCs, including ancillary data-entry equipment with trouble-shooting features.

To control critical parameters more strongly, closed-loop PLCs of various degrees of intricacy and configurations use a opinions from field devices. This gives more accurate plus more adaptive control.

A PLC can be designed through a hand-held device or downloaded from a personal computer (PC). Handily, a programmer can frequently be used for expanding documentation that identifies the system's construction and procedure. Sometimes this step is neglected. Documentation should be added to a consumer program for many reasons. Especially in energy management situations, the paperwork will help in the following ways

Operators will get system information to comprehend how the system performs.

Maintenance personnel can troubleshoot and maintain the machine.

Upgrading decisions will be simplified.

It can help answer questions, diagnose problems and make system modifications if requirements change.

It will allow easy reproduction of the machine if another unit installation is necessary.

3. 2 Industrial Automation Controllers

These devices are a fresh variety of controllers that unfit neatly into the PLC or Laptop or computer classification. They are generally used for special software settings such as movement and process control, specifically in complex closed-loop servo settings, such as those in robotic systems.

3. 3 Laptop or computer Process Control

Individual PLCs can be replaced by fully built in Personal computer process control plans. The energy administrator profits from constant, repeatable process control that integrates functions. Various packages can be found, and their request can help energy-saving efforts in, for example, the boiler house, refrigeration and presentation. They can be complemented by simulations packaged to test various "if" situations. Within the integration of the system, various means of electronic signal transmission are employed and could include, for example, radio occurrence (RF).

Investment in an activity optimizer will certainly reduce the precise energy use in a herb by using a sampling system and a control computer so the factory manages with the lowest amount of energy.

3. 4 Direct Digital Controls

Direct digital control (DDC) systems are usually found in large, complex procedures where the operations of many devices must be coordinated. Like PLCs, DDC systems include sensors and result devices. A DDC system, however, has a computer instead of a logic controller. The computer makes DDC systems adaptable and with the capacity of managing complex procedures because the setpoints can be improved dynamically and remotely by the theory of IP addresses designated for each and every device within the network. They also permit operators to start out and stop specific equipment remotely. Another strength of DDC systems is that they can store, analyse and screen data.

4. HVAC Automatic Control System

HVAC Handles, building automation (BAS), immediate digital control (DDC Control buttons) are at the heart of several energy management systems for energy personal savings. DDC Control Systems are mainly used in commercial HVAC control and energy management system applications in building automation.

DDC & building automation itself can be an energy management system which will save management companies and building owners hundreds of thousands if not millions of dollars every year by efficiently controlling air DDC/building

automation system (BAS) must have trim and respond features.

DDC is where mechanical and electro-mechanical systems and equipment are signed up with with microprocessors that communicate with each other and perhaps to a central computer. This computer and controllers in the building automation system can be networked to the internet or serve as a stand alone system for the neighborhood peer-to-peer controller network only. Additionally, the controllers themselves do not desire a computer to operate efficiently as many of these controllers are made to operate as stand-alone controllers and control the specific equipment they are simply assigned to control. With a few exceptions, each DDC or building automation controller retains their own programs and has the ability to talk to other DDC building automation controllers. It is important for the DDC or building automation controllers to talk to one another. When the network fails for reasons uknown then your system may still function (because the DDC controllers in building automation systems are stand-alone) but you won't function as successfully as designed. Building Automation & DDC Control Systems increases more and more complex after a while but it'll save in energy and maintenance costs if installed and designed properly. Energy Management Systems, DDC Settings Systems and Building Automation Systems (can be one in the same) are the way into the future and are exchanging older less efficient systems.

Fig 2, typical VAV DDC layout

4. 1 DDC/BAS features and functions

A set-up in a multi-story automated building could have many DDC building automation controllers portion different types of air conditioning and home heating equipment (DDC is not limited by just HVAC applications). Every building differs which is important to choose the correct control system and programs to regulate the many types of systems in a particular automatic building. For building automation systems to be effective, it's important that the machine is installed and tuned properly. Some important functions of a competent HVAC DDC building automation system are

a) DDC/building automation system (BAS) allow the owner to set up schedules of procedure for the equipment and light systems so that energy savings can be understood when the building or areas in the building are unoccupied;

b) Allow the equipment optimal focus on adaptive learning. Ideal start is allowing the gear to be induced in an bought and sequential manner automatically over a schedule before the building is reoccupied so that space establish points can be came to the realization before occupation. Adaptive learning allows the machine to compare space temp, outside air conditions, and equipment functions so that the equipment can be turned on at a proper time for you to ensure space set points are achieved before job.

c) Have lean and respond features. Based on area demand the set point for various heating and cooling sources will change relating to demand from the zones. Within a VAV system all the VAV boxes are offered from a central air controlling unit. If all the zones are at set in place point then your supply air temp set point of the environment handler is automatically improved to prevent mechanical cooling from occurring when it's unnecessary. When the zones grow warmer the resource air temperature establish point is automatically decreased to allow mechanical cooling to fulfill demand. Elderly systems have an individual supply air temperature established point of 55 Fahrenheit which requires the compressors to circuit even when it is not necessary;

d) Have the ability to monitor energy consumption including the capability to meter electric, gas, drinking water, steam, warm water, cold water, and fuel olive oil services;

e) With the appropriate mechanised system set-up, offer economizing based on enthalpy calculations and/or CO2 set in place point control;

f) Have algorithms as reset schedules for warming crops, static pressure control, and other systems where energy personal savings can be recognized through these predictive programs;

g) Offer load shedding when electric power companies are in peak demand and need business and industry to cut back on power usage to prevent black outs. Building automation systems allow the owner to cycle various things off like water heaters or taking in fountains where use of the things will not be recognized even though they are really off;

h) Provide ability to send alarms via email, pager, or cell phone to alert building professionals and/or technicians of expanding problems and system failures;

i) Management companies who acquire a good DDC/building automation system (BAS) can have DDC create to expenses tenants for energy consumption;

j) Have the communications skills to be included with other building automation control systems and TCP/IP category of protocols. It really is BACnet appropriate and other open up source communication process.

4. 2 LAN-WAN Configuration

The DDC can be configured as independent (localized) closed-system, or DDC open-system predicated on ease of access options required by a group of buildings supervised by a single company or property management company (centralized), or an individual property to be supervised and handled by its own (localized).

A closed protocol is a proprietary standard protocol used by a specific equipment supplier. An open process system runs on the protocol open to anyone, however, not published by the standards organization. A typical protocol system runs on the protocol available to anyone. It is created by way of a standards corporation.

Open Systems

An wide open system is thought as a system that allows components from different manufacturers to co-exist on a single network. These components

would not need a gateway to communicate with each other and would not require a maker specific workstation to imagine data. This would allow more than one vendor's product to meet a specific application necessity.

Fig 3, Integrated BACnet founded BROWSER BAS Control System Layout

5. High-performance Low-energy HVAC design

Recall the Benefits, In addition to the Automatic Control System request for energy conservation and high HVAC system performance, a renewable HVAC system design will achieve all aspects of comfort, energy saving, low initial and operational capital costs, and adds better performance with the DDC system, a good example of such inexperienced HVAC system would be an Optimal Air System.

Optimal Air systems uses less energy than typical systems on an annual basis, for example, In a conventional system, supply air temperatures run between 54F -57F from air handling device. With duct heating gain, the supply air varies from roughly 56F-59F from the air diffuser.

In Optimal Air System, source air heat run between 45-52F from the environment handling device to maximize energy usage, reduce first capital cost and improve moisture control. Optimal Air has for years been extensively found in grocery stores and it is gaining increasing acceptance in comfort cooling applications such as offices and institutions.

5. 1 Advantages

There are several advantages of Optimal Air that make it a stylish system for use in a wide variety of applications.

It Helps you to save Space and Reduces Energy and Construction Costs, increases the amount of practical heat that each CFM delivered to a zone can absorb. While 50F air may not appear much colder than 55F air, the delta T rises from 20F to 25F. That's a rise of 25%.

This influences the sizing of the ducts, air controlling units and fan motors, tending to be smaller and ends in a system that requires less space and uses less ability. In many applications, fans can use more power on a yearly basis than refrigeration (chillers, condensing devices, pumps, and compressors).

An exemplory case of annual 10-account building energy utilization of 200, 000 square-feet of HVAC components, the supporter energy use is high because the fans operate every hour the building is occupied providing least air movement, air flow air, heat, etc. In this case, an Optimal Air system would have a very real impact on overall energy costs.

Fig 4, Annual HVAC Energy Usage

5. 2 Less Wetness, more comfort

Optimal Air systems take more moisture from the return and ventilation air combination as it goes by over the chilling coil. The low water content in the supply air reduces the "Psychrometric balance point" moisture level in the conditioned space. This enables the space heat range to be set higher while attaining the same comfort level for occupants and further reduces the source air variety and fan vitality requirement.

5. 3 Quieter and Improve Indoor Air Quality (IAQ)

The lower air amount necessary for Optimal Air systems makes them quieter than typical systems. Fan sound technology is a function of enthusiast type, static pressure and air level. By reducing air quantity (and frequently the total supporter static pressure) Optimal Air systems create lower fan audio which can bring about more desirable space conditions. This reduced audio generation can be used to lessen the cost of any required sound attenuation in critical applications.

The lower required air size can even be used to reduce filter face velocities, allowing better filters to be used without high energy cost penalties. The lower air temperatures and resultant humidness levels also reduce the chance of mildew growth in the air managing products, ducts or the occupied space.

The example of the building above takes a source air of 26, 667 CFM. The HVAC system is floor by floor VAV air handling devices with a two chiller primary extra system, Optimal air works similarly well with applied rooftop systems or inside vertical self-contained units.

Table 1, HVAC system performance with optimal air system

Table 1 shows the HVAC system performance as the supply air heat range, to the duct, is lowered. It's important to differentiate between resource air temperature off of the cooling coil and supply air temperature into the duct.

To accommodate the lower supply air temperature, the cold water supply temp (CWST) was steadily lowered, the environment handling device coils deepened to allow for closer strategies, and chiller performance was modified to deal will the increased lift. For their basic operating variations, DX rooftop and self-contained systems may have another type of Optimal Air heat than a cold water system. When considering multiple system options, it's important to utilize Energy Analyzer for every in order to recognize your best option.

5. 4 Optimal Air Balance Point

Reduced lover energy must be "traded off" against increased refrigeration energy. This trade off varies with the kind of building, the sort temps control system, the type air-con system and geographic locale. Therefore, the "optimal" supply air temperature is different for every job. When only energy costs are one factor no thermal storage space is engaged, this optimal supply air temperature generally falls in the 47F -52F range. It can be determined by assessing total system energy usage with varying resource air heat using an energy research program.

5. 5 Space Design Temperature and Related Comfort

Temperature, humidity, air velocity and mean radiant heat range directly impact occupant comfort. Regular designs are usually based on retaining 75F and 50% RH (Relative Moisture) in the occupied space. Figure 5 shows the ASHRAE safe place where 80% of people involved in light office work are satisfied. As the comparative humidity is lowered, the space air temp can be raised but still provide occupant comfort[1].

The giving air condition from the air handling device is the generally control of the comparative wetness in the occupied space.

The internal water increases from people, kitchens, etc, as well as infiltration also play a part.

Fig 5, Comparative comfort chart

In most climates, the lower the source air temperature, the low the humidity ratio and the drier the space. Amount 5 shows practical heat percentage lines for classic, Optimal and low supply air conditions. As the area relative wetness is lowered, the space temperature set-point increases from 74F to 78F.

5. 6 ASHRAE Compliance

The 1999 and 2001 version of ASHRAE Standard 90. 1, Energy Standard for Properties except Low Rise Residential Complexes [2], has necessary requirements for refrigeration equipment and prescriptive requirements for supporter work. The Standard recognizes that Optimal Air systems improve fan work significantly and credits to account for improved lover performance. Furthermore, refrigeration system performance is rated at regular conditions or special desks are provided to account for non-standard operating conditions (as is the case with centrifugal chillers). In either case, ASHRAE Standard 90. 1 will not penalize Optimal Air systems.

5. 7 Design Considerations

Design of refrigeration and air handling equipment for an Optimal Air system is similar to the look of a typical air heat system. Attention must be paid, however, to air distribution, control buttons and duct design. Standard diffusers, when properly applied, will continue to work with Optimal Air.

Controls also require only slight changes from typical systems. Specifically, coding of economizer control buttons and supply air temps reset. Finally, the ducting system must be size for the reduced air level to have full benefit of the capital cost savings. Duct insulation and sweating also needs to be reviewed to give a hassle free system.

Not every building type is an excellent prospect for Optimal Air. When air amounts are dictated by air turnover rates, such as some health care applications, Optimal Air offers no advantages. Actually, there would be increased reheat costs. Office buildings are a solid applicant for Optimal Air. They have got high sensible warmth ratios and typically significantly less than 20% ventilation loads. Schools can even be a possibility. Generally speaking, as the percentage ventilation load rises, Optimal Air becomes less attractive.

Location and local climate also impact if Optimal Air is a good prospect. Locations where weather provides significant economizer hours between 45 and 55F will limit the personal savings. Ultimately, each job must be checked out by doing the suitable specific calculations. The following is highly recommended

Load and Balance Point computations, Space Temp Set-point evaluation, Design Load Calculation, Primary and Secondary System Selection, Parallel, mixing up or series VAV-Fan powered boxes, Perimeter Heating, Air Distribution, Diffusers (predicated on ventilation and the chuck distance calculation), Duct design (considering duct heat gain, sweating and insulation).

5. 8 System Life-Cycle Analysis

Evaluating different executive solutions is often part of an good proposal. Optimal Air systems are no different.

In the truth of Optimal Air, there may be no need to do any calculations because Optimal Air systems cost a lower amount to build (lower capital cost) and also have the same operating cost as normal systems (presuming the balance point was used for the design).

Duct sizing will decrease almost linearly with decrease in air level. The installed cost won't change linearly due to labor section. A 20% reduction in air amount can cause 80% savings of the 20% decrease or 16% overall personal savings in sheet metal cost.

On the plus area, there are less pounds of metallic and fewer man-hours to set up it. Around the minus side there is certainly more insulation. Terminal containers and diffusers will be a rinse since there are fewer of them but the equipment cost will be higher than regular equipment.

HVAC equipment will definitely cost a comparable. This is traditional because the air handling equipment will definitely cost less and refrigeration equipment will be marginally more. There is typically more capital invested in air handling than refrigeration.

Building envelope should be the same for new engineering. Regarding retrofit applications, it'll depend on the grade of the existing building.

The cost of space may also have to be evaluated. Not accounting for space personal savings is conservative. You will see space savings nonetheless they may be difficult to understand. If enough plenum level cost savings can be realized to include another floor within the same building envelope, then that rentable space should be accounted for.

Simple payback calculations do not take into account the expense of money, taxes and depreciation, inflation, maintenance or improves in the price tag on energy. A far more complete analysis will include Internal Rate of Go back (IRR) and world wide web present value (NPV). Inside the HVAC industry, many projects fail simple again (they are simply in the 5-year range) while passing IRR (they give a 25% rate of go back).

Software examination tools can be used to perform both energy and life-cycle evaluation including simple payback, IRR and NPV.

6. Conclusion

Building owners and designers confronted with increased concerns for energy preservation and environmental stewardship seek out affordable system options for their projects.

The Auto Control system, included with a high-performance low-energy HVAC system as the Optimal Air system can deliver both low first costs and reduced energy costs in a fresh engineering and retrofit applications. This integrated system will not only meet up with the efficiency and sustainability of its performance at the desired set-parameters, but when designed with advanced selection tools, installed with the most advanced DDC, and backed by trained providers, allow building owners to compare expected energy use to real performance and environmental influences reduction.